WhatsApp

Automatic Sliding Door Systems

An entrance defines the first and last impression of any building. ACCESSCO supplies, installs, and maintains auto sliding doors engineered to perform with consistency and precision across the full spectrum of commercial environments. From healthcare facilities to corporate headquarters, our automatic sliding door systems are specified in settings where long-term reliability and compliance are non-negotiable.

Engineered with a high-performance motor and precision control system to deliver quiet, stable, and consistent door movement.

Equipped with intelligent sensors and safety mechanisms that detect movement, position, and resistance to prevent impact and ensure user safety.

Designed to support single, bi-parting, and telescopic configurations, and adaptable to glass, aluminium, steel, timber, and framed door systems.

Refined Engineering

Refined Engineering for Everyday Operation

ACCESSCO Automatic Sliding Doors are designed with a balanced electromechanical system to deliver smooth, consistent movement.

Its construction supports long operating cycles while maintaining quiet performance in busy environments.

Well-Suited for High-Traffic Entrances

This system is ideal for commercial and healthcare environments where doors operate continuously throughout the day. 

It supports efficient pedestrian flow while maintaining safety and operational reliability.

Technical Description

Operator Dimension

Height 100mm x Width 160mm

Main Power Supply

Auto Switch 90~250V +/- 50/60 Hz

Power Consumption

max 180w

Auxilliary Voltage

24V DC

Drive Unit

40V 100MW Made in Germany

Max Door Weight

Single - 150kg upgrade ~200kg
Bi-parting 240kg upgrade ~360kg

Max Opening Speed

up to 1400mm/sec (Bi-parting)

Max Closing Speed

up to 1000mm/sec (Bi-parting)

Hold Open Time

0 ~ 60sec

Max Opening Width

Single - 800~2500mm
Bi-Parting - 800~3200mm

Ambient Temperature

-15°C to +50°C

Humidity Range

up to 85%

Intelligent Processor

Self Learning & Auto Error Detection

Safety Compliance

DIN18650-1 : 2010
EN16005-1 : 2010/AC:2010

Mechanical Performance

Test 1 = 1,000,000 Cycle

& Durability Test

Test 2 = 2,000,000 Cycle

Technical Description

Still have questions?

Specifying Correctly: What to Consider

Selecting a sliding door contractor requires careful evaluation beyond product aesthetics or price. The specification decisions made at the outset determine how the system performs years into its life cycle.

Safety and Compliance

The operator must comply with recognised international standards. ACCESSCO’s system holds certification to DIN 18650-1:2010 and EN 16005-1:2010/AC:2010, which govern power-operated pedestrian doorsets. In any commercial or public-access building, these certifications form part of the minimum required standard.

Core Specification Points

Evaluate the motor origin, drive type, and processor intelligence. A self-learning system with auto error detection reduces the burden of manual recalibration and supports consistent performance over time. Systems specified on cost alone often incur a higher total cost of ownership over 3 to 5 years.

Traffic Volume and Durability

The operating demands of a hospital’s main entrance differ substantially from those of a boutique retail unit. ACCESSCO’s operator has been independently tested to 2,000,000 operating cycles, providing specifiers with a documented durability benchmark.

Opening Width Requirements

Confirm that the configuration supports your required clear opening width. Single-leaf and bi-parting options serve different entrance geometries, and the correct selection affects both function and the architectural finish of the installation.

Safety Sensor Capability

The sensor suite should operate independently across movement, position, and resistance detection. A system that relies on a single detection method introduces risk in high-footfall or unpredictable pedestrian environments.

Operating Environment Conditions

Entrances exposed to humidity, heat, or significant temperature variation require a verified operating range. A well-specified automatic sliding door commercial installation accounts for these conditions from the outset. ACCESSCO’s system is rated from -15°C to +50°C with a humidity tolerance of up to 85%, covering the full range of conditions encountered in Singapore’s climate and in semi-outdoor or cold-room-adjacent installations.

Why Clients Specify ACCESSCO

Feature Description

BCA Registered and BizSafe Certified

ACCESSCO holds registration with Singapore’s Building and Construction Authority and BizSafe certification. As a compliant automatic sliding door systems supplier, every installation is carried out in accordance with Singapore’s regulatory and workplace safety framework.

Multi-Layered Safety Sensing

The operator’s sensor system independently detects movement, position, and mechanical resistance, reducing the risk of contact incidents in demanding pedestrian environments. This capability is particularly valued in hotel and mall automatic doors, and in healthcare settings where entrance safety is a primary operational concern.

Configuration Flexibility

The system accommodates single, bi-parting, and telescopic configurations across glass, aluminium, steel, timber, and framed constructions — including frameless automatic glass door applications. As a sliding door supplier serving a broad range of sectors, ACCESSCO provides the configuration range to meet both functional and design briefs within a single supply relationship.

Verified Environmental Performance

Rated performance across -15°C to +50°C and humidity up to 85% confirms suitability for Singapore’s climate as well as the more demanding conditions found in semi-outdoor covered walkways and facilities with controlled thermal environments.

German-Engineered Drive Unit

The 40V 100MW drive unit is manufactured in Germany. The precision and consistency of the drive mechanism are foundational to the system’s ability to sustain quiet, stable operation at high cycle volumes.

Documented Durability

Testing to 2,000,000 operating cycles provides a quantified reference point for asset planning. For facilities managers and procurement teams, this is the difference between a manufacturer’s assurance and an independently verified performance record.

Strengths and Practical Considerations

Having delivered sliding door systems across a broad range of sectors, we offer an objective assessment for those at the specification stage.

Where this system is particularly well suited: The combination of wide opening width range, high transit speed, and independent sensor detection makes this system well matched to high-footfall environments, including malls, offices, hospital main entrances, and airport-adjacent retail. The self-learning processor adapts to usage patterns over time, reducing the frequency of manual adjustments in consistently busy locations.

Where early planning is advisable: Where structural constraints limit available header depth, the operator dimensions (H100mm x W160mm) should be incorporated into architectural drawings at an early stage rather than resolved during installation. Telescopic configurations carry tighter installation tolerances and benefit from a site survey before specification is finalised. These are not limitations of the product; they are the conditions under which experienced sliding door installation practice makes a material difference to the outcome.

Sectors and Applications

Sector Application

Healthcare & Medical Facilities

Hands-free access and hygiene management are fundamental operational requirements

Retail & Shopping Centres

High cycle volumes and fast transit speeds are essential

Hospitality & Hotels

Automatic doors at entrances contribute to a seamless arrival experience

Offices & Corporate Buildings

Integration with access control and architectural finishes

Transportation & Public Infrastructure

Compliance and continuous availability are critical

F&B, Government & Institutional

Operational reliability and regulatory compliance requirements

Discuss Your Project with ACCESSCO

As an established automatic sliding door systems supplier in Singapore, ACCESSCO engages with architects, facilities managers, and developers from early specification through to post-installation maintenance.

Whether the scope involves a focused installation at a single entrance or a multi-site programme requiring an experienced contractor, our approach is consultative throughout: we provide the technical detail, compliance documentation, and experienced guidance that allows clients to make well-informed decisions.

Contact us to arrange a consultation, or download the product brochure  for complete technical documentation.

Frequently Asked Questions

The decision is primarily governed by the required clear opening width and available header space.

A single-leaf configuration supports openings up to 2,500mm; bi-parting extends this to 3,200mm and is generally preferred for wider entrances or where symmetrical presentation matters, such as hotel lobbies or hospital main entrances.

A site visit allows us to confirm the most appropriate configuration for your specific conditions.

The operator is compatible with glass, aluminium, steel, timber, and framed door systems, making it adaptable to virtually any automatic sliding door commercial project, regardless of the specified architectural finish. Material selection is typically informed by the project’s aesthetic requirements, security specification, and structural loading. Our team is available to advise during the specification stage.

Yes. The system accommodates opening widths from 800mm to 2,500mm in single configuration and up to 3,200mm in bi-parting, providing flexibility across a wide range of entrance dimensions without requiring a different operator platform.

The operator has been tested to 2,000,000 operating cycles, providing a verified durability reference for long-term asset and maintenance planning.

The system is rated for ambient temperatures between -15°C and +50°C, with a humidity tolerance of up to 85%, which accommodates conditions found in covered walkways, semi-outdoor entrances, and Singapore’s climate generally. For fully exposed outdoor installations, we recommend discussing the specific site conditions during the initial consultation.